"8840A"의 두 판 사이의 차이
(새 문서: DMM, Fluke 8840A/8842A <ol> <li>FLUKE 8840A <ol> <li>설명 <ol> <li>8842A보다 측정범위가 낮은값에서 한 단계 좁다. <li>0.005%. DCV 200m,2,20,200,1000V / DCA 2A / R 20...) |
|||
1번째 줄: | 1번째 줄: | ||
− | DMM, Fluke 8840A | + | DMM, Fluke 8840A |
<ol> | <ol> | ||
+ | <li>링크 | ||
+ | <ol> | ||
+ | <li> [[전자부품]] | ||
+ | <ol> | ||
+ | <li> [[DMM]] | ||
+ | <ol> | ||
+ | <li> [[8840A]] - 이 페이지 | ||
+ | <li> [[8842A]] | ||
+ | </ol> | ||
+ | </ol> | ||
+ | </ol> | ||
<li>FLUKE 8840A | <li>FLUKE 8840A | ||
<ol> | <ol> | ||
7번째 줄: | 18번째 줄: | ||
<li>8842A보다 측정범위가 낮은값에서 한 단계 좁다. | <li>8842A보다 측정범위가 낮은값에서 한 단계 좁다. | ||
<li>0.005%. DCV 200m,2,20,200,1000V / DCA 2A / R 200,2k,20k,200k,2M,20M | <li>0.005%. DCV 200m,2,20,200,1000V / DCA 2A / R 200,2k,20k,200k,2M,20M | ||
+ | <li>Option -05 GPIB | ||
+ | <li>Option -09 RMS AC(ACV ACI) | ||
</ol> | </ol> | ||
<li>이력 | <li>이력 | ||
<ol> | <ol> | ||
− | <li>18/04/20- | + | <li>18/04/20 - 총 64,179원 |
<li>18/05/14 투고기술에 도착함. 100V를 220V로 변경하고 DC전압 측정. 문제없음 | <li>18/05/14 투고기술에 도착함. 100V를 220V로 변경하고 DC전압 측정. 문제없음 | ||
</ol> | </ol> | ||
− | <li> | + | <li>내부 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<gallery> | <gallery> | ||
− | image: | + | image:8840_01_001.jpg | 윗면 |
− | image: | + | image:8840_01_002.jpg | 아랫면, 옵션 GPIB보드, 옵션 AC 측정보드가 있다. |
− | |||
− | |||
− | |||
</gallery> | </gallery> | ||
− | + | <li>메인 보드 | |
− | |||
− | |||
− | |||
− | <li> | ||
<gallery> | <gallery> | ||
− | image: | + | image:8840_01_003.jpg | Front/Rear Switch |
− | image: | + | image:8840_01_004.jpg | 전류측정 저항 |
+ | image:8840_01_005.jpg | Fluke 715680 [[ADC]] | ||
+ | image:8840_01_006.jpg | Motorola SZA263 (=LTFLU) [[전압표준]] | ||
+ | image:8840_01_007.jpg | SR0085V2-3 MCU(~Z80), D8279C Keyboard/Display Controller, : Intersil X2804AP EEPROM 512 Byte Calibration Memory | ||
+ | image:8840_01_008.jpg | bend up 90', sheild A/D (=L-shaped shield plate) | ||
+ | image:8840_01_009.jpg | Dionics Di514BR High Voltage VF Display Driver, EL SALVADOR SN74LS248 BCD-to-7Segment Decoders/Drivers, SN74LS259 8-Bit Addressable Latch, UDN2585A 8-ch Source Drivers | ||
+ | image:8840_01_010.jpg | Fluke 700013 Quad Analog Switch | ||
+ | image:8840_01_011.jpg | voltage divider, precision resistors networks | ||
+ | image:8840_01_012.jpg | AD40323, three-pole, low-pass analog filter, Bessel response with corner frequency at 7 Hz, giving approximately 50 dB of rejection at 50 Hz. | ||
</gallery> | </gallery> | ||
− | <li> | + | <li>옵션 GPIB보드, IEEE-488 Interface PCA |
<gallery> | <gallery> | ||
− | image: | + | image:8840_01_013.jpg | MC3447 bidirectional bus transceiver |
− | image: | + | image:8840_01_014.jpg | SR0086V-4 GPIB IC, MDP1603(16pin 03 isolated) MDP1401(14pin 01 bussed) |
+ | image:8840_01_015.jpg | ||
+ | image:8840_01_016.jpg | 1984 John Fluke Mfg Co Inc | ||
</gallery> | </gallery> | ||
− | <li> | + | <li>옵션 AC 측정보드, Option -09, True RMS AC circuit |
<gallery> | <gallery> | ||
− | image: | + | image:8840_01_017.jpg |
− | image: | + | image:8840_01_018.jpg |
− | image: | + | image:8840_01_019.jpg | AC 전압범위에 따라 /500 /5 낮추고, x0.5, x5, x500 높인 후 RMS 변환한다. |
+ | image:8840_01_020.jpg | 1.11M, 222k, 2.245k | ||
+ | image:8840_01_021.jpg | R7032-1, R8378-1 reed relay | ||
+ | image:8840_01_022.jpg | LF356N JFET Input Operational Amplifiers, DG211CJ Quad SPST CMOS Analog Switches, NE5532N Dual Low Noise Operational Amplifier | ||
+ | image:8840_01_023.jpg | AD637JD High Precision, Wideband RMS-to-DC Converter | ||
</gallery> | </gallery> | ||
− | |||
</ol> | </ol> | ||
</ol> | </ol> |
2020년 5월 9일 (토) 17:01 판
DMM, Fluke 8840A
- 링크
- FLUKE 8840A
- 설명
- 8842A보다 측정범위가 낮은값에서 한 단계 좁다.
- 0.005%. DCV 200m,2,20,200,1000V / DCA 2A / R 200,2k,20k,200k,2M,20M
- Option -05 GPIB
- Option -09 RMS AC(ACV ACI)
- 이력
- 18/04/20 - 총 64,179원
- 18/05/14 투고기술에 도착함. 100V를 220V로 변경하고 DC전압 측정. 문제없음
- 내부
- 메인 보드
- 옵션 GPIB보드, IEEE-488 Interface PCA
- 옵션 AC 측정보드, Option -09, True RMS AC circuit
- 설명