"계장"의 두 판 사이의 차이

215번째 줄: 215번째 줄:
 
image:espec_oven2_005.jpg
 
image:espec_oven2_005.jpg
 
</gallery>
 
</gallery>
</ol>
 
</ol>
 
<li>산업용 전기계장
 
<ol>
 
<li>PLC
 
<ol>
 
<li>Keyence KZ-A500
 
<ol>
 
<li>전체
 
<ol>
 
</ol><gallery>
 
image:plc1_001.jpg
 
image:plc1_002.jpg
 
</gallery>
 
<li>파워
 
<gallery>
 
image:plc1_power_001.jpg
 
image:plc1_power_002.jpg
 
image:plc1_power_003.jpg
 
image:plc1_power_004.jpg
 
</gallery>
 
<li>CPU
 
<gallery>
 
image:plc1_cpu_001.jpg
 
image:plc1_cpu_002.jpg
 
image:plc1_cpu_003.jpg
 
image:plc1_cpu_004.jpg
 
image:plc1_cpu_005.jpg
 
image:plc1_cpu_006.jpg
 
image:plc1_cpu_007.jpg
 
image:plc1_cpu_008.jpg
 
image:plc1_cpu_009.jpg
 
image:plc1_cpu_010.jpg
 
image:plc1_cpu_011.jpg
 
image:plc1_cpu_012.jpg
 
image:plc1_cpu_013.jpg
 
image:plc1_cpu_014.jpg
 
image:plc1_cpu_015.jpg
 
image:plc1_cpu_016.jpg
 
image:plc1_cpu_017.jpg
 
image:plc1_cpu_018.jpg
 
</gallery>
 
<li>Input
 
<gallery>
 
image:plc1_in_001.jpg
 
image:plc1_in_002.jpg
 
image:plc1_in_003.jpg
 
image:plc1_in_004.jpg
 
image:plc1_in_005.jpg
 
image:plc1_in_006.jpg
 
image:plc1_in_007.jpg
 
image:plc1_in_008.jpg
 
image:plc1_in_009.jpg
 
</gallery>
 
<li>Output
 
<gallery>
 
image:plc1_out_001.jpg
 
image:plc1_out_002.jpg
 
image:plc1_out_003.jpg
 
image:plc1_out_004.jpg
 
image:plc1_out_005.jpg
 
image:plc1_out_006.jpg
 
image:plc1_out_007.jpg
 
</gallery>
 
</ol>
 
 
</ol>
 
</ol>
 
<li>가정용 대기전력 차단기 Standby power cut-off outlet
 
<li>가정용 대기전력 차단기 Standby power cut-off outlet
312번째 줄: 247번째 줄:
 
image:pnctech01_004.jpg | 통신4
 
image:pnctech01_004.jpg | 통신4
 
</gallery>
 
</gallery>
<li>회로 차단기
 
<ol>
 
<li>Circuit Protector
 
<ol>
 
<li>분해 보고서
 
<li>Mitsubishi Electric, CP30-BA, 3A급은 6A에서 1초 이내에 차단됨
 
<gallery>
 
image:breaker1_001.jpg
 
image:breaker1_002.jpg
 
image:breaker1_003.jpg
 
image:breaker1_004.jpg
 
image:breaker1_005.jpg
 
image:breaker1_006.jpg
 
</gallery>
 
<li>Daco(대륙전기) DCP31PSH - 박천길 기증품
 
<ol>
 
<li>대륙 회로보호용차단기 카달로그 - 74p
 
<li>전류에 따른 차단 곡선
 
<gallery>
 
image:breaker02_007.png | 정격전류 얼마 이상이면 trip된다는 규격이 없는데 동작한다.
 
image:breaker02_008.jpg | 100도 넘게 뜨거워지면 기구적으로 뒤틀려 차단되는 듯.
 
</gallery>
 
<li>분해 사진
 
<gallery>
 
image:breaker02_001.jpg | 정격 15A 1.5kA에서 차단됨.
 
image:breaker02_002.jpg | 전면에서 스크류 체결로 고정함.
 
image:breaker02_003.jpg | line와 load가 구분됨. 다 이유가 있을 듯.
 
image:breaker02_004.jpg | 왼쪽, 코일이 있는 쪽이 load 이다.
 
image:breaker02_005.jpg | Trip 되었을 때
 
image:breaker02_006.jpg | 6.5m오옴에 15A흐르면 1.5W 소모된다.
 
</gallery>
 
</ol>
 
</ol>
 
<li>ELCB; Earth Leakage Circuit Breaker
 
<ol>
 
<li>대륙, 50A용, 차단 5kA, 30mA, 0.03초 이내
 
<gallery>
 
image:mc1_000.jpg
 
image:elcb1_000.jpg
 
image:elcb1_001.jpg
 
image:elcb1_002.jpg
 
image:elcb1_003.jpg
 
image:elcb1_004.jpg
 
image:elcb1_005.jpg | 이 상태에서 납땜해야 한다. 조립 및 검사성이 나쁨
 
image:elcb1_006.jpg
 
image:elcb1_007.jpg
 
image:elcb1_008.jpg
 
image:elcb1_009.jpg
 
image:elcb1_010.jpg
 
image:elcb1_011.jpg
 
image:elcb1_012.jpg | 웨지본딩
 
image:elcb1_013.jpg
 
image:elcb1_014.jpg
 
image:elcb1_015.jpg | 인가전압보다 코일은 위상이 +90도이다.
 
</gallery>
 
<li>??, ?A용, 차단 ?A(열나면 차단), - 16/09/09 초이미디어 최인철 제공
 
<gallery>
 
image:elcb02_001.jpg
 
image:elcb02_002.jpg
 
image:elcb02_003.jpg
 
image:elcb02_004.jpg
 
image:elcb02_005.jpg
 
image:elcb02_006.jpg
 
image:elcb02_007.jpg | ZCT
 
</gallery>
 
<li>투고기술 배전반에 많음
 
<gallery>
 
image:elcb03_001.jpg
 
</gallery>
 
<li>LS산전, 누전차단기, EBS32Fb, 30A 30mA - 17/07/06 박천길, 야외 교통시설 설치용
 
<gallery>
 
image:elcb04_001.jpg
 
image:elcb04_002.jpg
 
image:elcb04_003.jpg
 
image:elcb04_004.jpg
 
image:elcb04_005.jpg
 
image:elcb04_006.jpg
 
image:elcb04_007.jpg
 
image:elcb04_008.jpg
 
image:elcb04_009.jpg
 
image:elcb04_010.jpg
 
</gallery>
 
</ol>
 
<li>EOCR; Electronic Over Current Relay
 
<gallery>
 
image:mc1_000.jpg
 
image:eocr1_001.jpg
 
image:eocr1_002.jpg
 
image:eocr1_003.jpg
 
image:eocr1_004.jpg
 
image:eocr1_005.jpg
 
image:eocr1_006.jpg
 
image:eocr1_007.jpg
 
image:eocr1_008.jpg
 
image:eocr1_009.jpg | 쓰루홀 납땜이 아님. 고정안돼 흔들려...
 
image:eocr1_010.jpg
 
image:eocr1_011.jpg | AC를 DC로 만들 때 제너가 전압을 자르는데 계속 뜨거워져...
 
</gallery>
 
<li>MC; Magnetic Contactors
 
<ol>
 
<li>허민 제공
 
<gallery>
 
image:mc1_000.jpg
 
image:mc1_001.jpg
 
image:mc1_002.jpg
 
image:mc1_003.jpg
 
image:mc1_004.jpg
 
image:mc1_005.jpg
 
image:mc1_006.jpg
 
image:mc1_007.jpg
 
image:mc1_008.jpg
 
image:mc1_009.jpg
 
image:mc1_010.jpg
 
image:mc1_011.jpg
 
image:mc1_012.jpg
 
image:mc1_013.jpg
 
image:mc1_014.jpg
 
image:mc1_015.jpg
 
image:mc1_016.jpg
 
image:mc1_017.jpg
 
image:mc1_018.jpg
 
image:mc1_019.jpg
 
</gallery>
 
<li>2016/08 솔라세라믹, 인버터 고장났을 때
 
<gallery>
 
image:mc2_001.jpg
 
image:mc2_002.jpg
 
image:mc2_003.jpg
 
image:mc2_004.jpg
 
image:mc2_005.jpg
 
</gallery>
 
</ol>
 
<li>MCCB; Molded Case Circuit Breakers
 
<ol>
 
<li>30A
 
<gallery>
 
image:mccb1_001.jpg
 
image:mccb1_002.jpg
 
image:mccb1_003.jpg
 
image:mccb1_004.jpg
 
image:mccb1_005.jpg
 
image:mccb1_006.jpg
 
image:mccb1_007.jpg
 
image:mccb1_008.jpg
 
image:mccb1_009.jpg
 
image:mccb1_010.jpg
 
image:mccb1_011.jpg
 
image:mccb1_012.jpg
 
image:mccb1_013.jpg
 
image:mccb1_014.jpg
 
image:mccb1_015.jpg
 
image:mccb1_016.jpg
 
image:mccb1_017.jpg
 
image:mccb1_018.jpg
 
image:mccb1_019.jpg
 
</gallery>
 
<li>10A - 단선으로 차단되어 고장.
 
<ol>
 
<li>동영상
 
<ol>
 
<li>동영상 , , https://youtu.be/eMxJx7NveqI
 
</ol>
 
<li>분해 사진
 
<gallery>
 
image:mccb2_001.jpg
 
image:mccb2_002.jpg
 
image:mccb2_003.jpg
 
image:mccb2_004.jpg
 
image:mccb2_005.jpg
 
image:mccb2_006.jpg
 
image:mccb2_007.jpg
 
image:mccb2_008.jpg
 
image:mccb2_009.jpg
 
image:mccb2_010.jpg
 
image:mccb2_011.jpg
 
image:mccb2_012.jpg
 
image:mccb2_013.jpg
 
image:mccb2_014.jpg
 
image:mccb2_015.jpg | 바람구멍이 있다.
 
image:mccb2_016.jpg
 
image:mccb2_017.jpg
 
image:mccb2_018.jpg
 
image:mccb2_019.jpg
 
</gallery>
 
</ol>
 
</ol>
 
<li>TOR;thermal overload relay(열동 과부하 계전기); MC에 붙어 있음.
 
<ol>
 
<li>카탈로그
 
<ol> ,
 
</ol>
 
<li>동영상
 
<ol> , https://youtu.be/A5x589cA1mo
 
</ol>
 
<li>사진
 
<gallery>
 
image:tor1_001.jpg
 
image:tor1_002.jpg
 
image:tor1_003.jpg
 
image:tor1_004.jpg
 
image:tor1_005.jpg
 
image:tor1_006.jpg
 
image:tor1_007.jpg
 
image:tor1_008.jpg
 
image:tor1_009.jpg
 
image:tor1_010.jpg
 
</gallery>
 
</ol>
 
</ol>
 
 
</ol>
 
</ol>
 
</ol>
 
</ol>

2019년 6월 15일 (토) 23:00 판

전기 계장; instrumentation

  1. 기타 장치
    1. Tsuruga 452A Digital Meter Relay(전압을 측정해서 relay 동작시키는)
      1. Quick Manual
          Tsuruga, 452A-49-A-5-29 모델, 0~5V input, AC100~240V 전원, DC24V out, ~20mA out
      2. dewpoint meter, Telemax Corporation TED-2
      3. 외관
      4. 외부 SMPS, DC 24V 상시 출력 전원 모듈
      5. 내부 전원 + 아날로그 입력 보드
        1. 전체
        2. 내부 SMPS 전원
        3. 아날로그 입력 보드
      6. 디스플레이 + 디지털 제어 보드
      7. 아날로그 20mA 출력 보드
      8. 릴레이 보드
    2. 아투시스템 디스플레이 보드(허민사장이 17/09/11 가져옴)
      1. RS232 데이터를 6자리 숫자로 표시하는 보드. 이를 PC에서 받고 싶어서
      2. 출처 , https://electronics.stackexchange.com/questions/57771/need-a-led-display
      3. 사진
    3. 릴레이보드 - 박천길 기증품
    4. 온도 컨트롤러
      1. 솔라세라믹 발열유리용 UTH-2K
      2. 솔라세라믹 발열유리용 , Acts238, UTH-170
      3. 솔라세라믹 발열유리용 AC40V
      4. 남일 엔지니어링 - S302CR 온도 컨트롤러(제어 출력은 4~20mA)
        1. 외관
        2. 전면 조작/표시부
        3. 주기판
        4. 전원 - SMPS를 사용하지 않고 linear regulator(+5, +9V) 사용
        5. 제어
        6. PCB 밑면에서 리드 구부림 및 절단
      5. YAMATAKE회사의 SDC15, C15TVVRA0300 콘트롤러 -> Azbil Corporation
        1. 규격 - 146p
            C15(시리즈) T(패널마운트) VV(SSR을 위한 전압펄스출력) R(RTD입력 PT100), A(AC 전원), 03(출력 및 RS485), 0(부가기능없음), 0(UL 승인품 아님)
        2. 사진
    5. ESPEC 진공오븐 콘틀롤러
      1. 보드 #1
        1. 전체
        2. 주요 부분
      2. RTD 온도 센서 보드(?)
    6. 가정용 대기전력 차단기 Standby power cut-off outlet
      1. 홀센서 사용 - Dosel 상표
        1. 14/12/30
        2. 14/11/05 얻음, 16/09/21 촬영
      2. CT 사용(원가 절감을 위해) - 2017/10/10 촬영
    7. PNC테크 전력감시용 보드에서